Conditions measuring procedure and submission of data

The Noise nuisance recorders should be placed centrally for one or two weeks in the most normative place (living space within the framework of the Building Decree). The case should be closed with a lock. The residents can therefore not do anything to the case. During the measuring session, the residents should be quiet when activating the meter. In other words: no radio/TV turned on and all household appliances should be quiet for a while (furnace, washing machines, etc). Own speech and walking movements should be minimized as well. Furthermore, windows and doors should be closed during pressure moments. The person installing the measuring case will take a picture of the installation and briefly describe the chosen room and the relationship to the construction of the walls and floors (concrete/wooden floor). It should also be briefly stated if the reverberation field was high or low in the room (much/little absorption, curtains/rugs/etc). This data has to be provided with the order when you send the files to Neighbor Noise Control

The meter should be set specifically for the measurement values Laeq and LAmax following the Activities decree for Environmental Protection. The measured proposed values are LAeq and LAmax.

We act as an independent party. This means that we do not communicate about internal and measurement-technical matters. If communication is necessary, we will always consult with the client beforehand. It is also important that the starting date of the measurements is corresponded with the residents by telephone only, without being known to the surrounding residents and users. This is due to (consciously) influencing the measurement session.